Anti-Backflow Control Strategies for Grid-Connected PV Systems: Principles, Schemes, and Applications发表时间:2025-07-03 10:46 PV Anti-Backflow Control is a critical technology ensuring the safe and stable operation of grid-connected photovoltaic (PV) systems. Its core objective is to prevent reverse power flow from PV generation into the grid, thereby safeguarding both the grid infrastructure and PV equipment. The mainstream control schemes are as follows: 1. Power Cutoff Scheme (Fast Trip Scheme / Switch-Based Scheme): detecting islanding operation or reverse current flow (i.e., PV current flowing towards the grid), the device immediately trips the grid interconnection breaker or designated PV switch/inverter. If backflow persists, it progressively disconnects additional units. When load increases cause grid current to flow towards the load, the device determines insufficient PV output and automatically reconnects some units. it incurs PV curtailment losses, potentially increasing user electricity costs, and represents a "hard" protection method. 2. Power Regulation Scheme (Soft Regulation Scheme / Meter & Inverter-Based Scheme): monitoring bus power, current magnitude, and direction. Upon detecting reverse current flow (backflow) towards the grid: (e.g., RS485) to the corresponding inverter, which rapidly reduces output power until the reverse current approaches zero. interfaces to a data concentrator (often integrated into an anti-backflow box). The concentrator aggregates signals from the anti-backflow meter/CTs, calculates total backflow power, and coordinates multiple inverters to reduce output synchronously via communication commands. backflow prevention without PV curtailment. The core device is the anti-backflow meter (e.g., ADL400N), featuring high accuracy, fast response, bidirectional metering, and communication interfaces (supporting interaction with inverters or EMS). Applicable to both single-inverter (single/three-phase) and multi-inverter PV systems. 3. Energy Management System (EMS) Scheme: real-time PV export power and current direction signals and uploads them to the EMS. Based on preset strategies and real-time data analysis, the EMS sends power regulation commands to PV inverters (or storage PCS) to dynamically control their output and prevent backflow. utilization. The system offers powerful functionality, including data storage, reporting, HMI, and advanced management features. However, system configuration and costs are relatively higher. Universal Core Mechanism of Anti-Backflow Control: When current direction reverses (flowing towards the grid):
Importance of Anti-Backflow Control:
Scheme Selection Recommendations:
commercial/industrial systems are better suited for multi-inverter coordinated schemes or EMS schemes.
curtailment losses, enhanced safety).
backflow prevention performance targets and grid interconnection standards. |